They are little ants that just came. Or is there anything else I can check? The old "off" tripper was fractionally bent. Advice? not sure what is the problem. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. You may need to adjust the meshing of the timer motor gear so it runs the clock. Second thing to check is the dial bent or warped, in that area where the on tripper is? Much like your timer pointer, the trippers can become loose and move around as well. I dont see any debris blocking the off dog. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. Did the power recently go out or has the circuit breaker tripped? The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. My timer doesnt seem to be working or my pump in either speed. Wont work manually or by timer function. T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Thanks Reid. Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. The clock not turning on your Intermatic pool timer is a common issue. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Above you said to connect white to A. and Black to 1what do I do with red? There is a switch control panel and replaced the 20amps DP switch as well. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. When I turned it back on now the pool clock goes backwards. David, check the wiring, the power in and power out wires may be reversed. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. If I have to tell you which terminals to measure, you shouldnt be doing this! You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Intermatic timer won't turn on/off pump. | Trouble Free Pool The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. Hi Jeff, it could be that the terminals in the rear of the clock mechanism are fuse-welded together, and not separating like normal, when the on/off switch is flipped. The 2,810 sq. the problem lies, where the power dies as they say. Today is the second day that I have had to turn it on manually. the timer was directly plugged into a gfci and the pump directly into the timer. Any ideas? Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. There is a lot of water that is making the cover sink and I dont want to keep filling the pool with water trying to get the cover up/. I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. What was the fix?? Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. I went to the control panel and saw that the timer needle stopped just after the start pointer. "primaryImageOfPage": {
And does the switch look worn, where the tripper engages? Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. The power should run from the breaker, to the timer, to the pump. I have the Intermatic T103 autotimer on my pool. For extra safety, shut-off the Pool breaker on the main home panel too. The yellow clock face should sit down in the timer. "url": "https://blog.intheswim.com/"
I have Model T40004RTe. Hi Doug, Check the wiring. If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. Push down on the timers until they snap into place. Karl, good question. I manually turn it on timer is running, it will trip pump OFF. Articles and resources for swimming pool owners and DIYers. Then turn the breaker, that the time clock is connected to, off and back on again. I had to order new trippers as mine have been straightened too many times. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
However, intermittently after the ON tripper switches pump on the pump will stop. it could also be a failing breaker, but that would be a last resort. Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. It just seems to have a weak start?? To do this, pull the yellow-faced time dial (clockface) toward you. Do you have an answer to why my pump wont turn off or on? Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. Phil. Is this broken? There should be an off pin and an on pin. Also known as an RCD (residual current device) in Australia and the UK. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Go for it, a little maintenance expense. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. 120Volt Tork 1101 timers can be fixed with repair parts. Could also be grit or insects inside of the gears of the clock motor. Replaced complete new timer assuming 5 years perfect service probably wore it out. Check that dial is not warped. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Should You Get a Pool Pump Timer? Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. Turn the metal bar until it contacts one of two plastic side tabs. Thanks. Thank you for choosing Intermatic! Any other thoughts? Theres an issue with the wiring between the circuit breaker and the timer. The gears in mechanical timers can get damaged. Ask Your Own Pool and Spa Question Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. That should quiet it down. Open following links to identify timer and then add a comment. Everythings OK now, unit works just fine. How Do You Set A Pool Pump Timer? - Pool Pro Answers If the pool timer is not keeping the correct time or losing time, there may be a simple fix. You will want to make sure the manual switch under the timer wheel is pushed to the on position. The circuit is protected by two ganged breakers. Related Reading: Should You Get a Pool Pump Timer? My intermatic pool timer will not automatically turn on. I - JustAnswer Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. (usually not). I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. Thank you. If you cant see an issue with the gears, then it could be the timer motor. how should I lubricate those? You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Timer must be reset for current time after power outage. Reference Manual & Buyer's Guide Another Brick in the Make sure the middle time pointer is tight. (For outside light timer) The one before was original to the house & I had no trouble. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. Pool Pump Timer Not Working - Pool Research I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. Wired correctly, #10 wire, nothing. Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. did i do something incorrectly? My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. As it get cooler you can cut it down to 5 or 6 hr a day . These are the trippers that came with the time clock. IT happens, so I ask. I visually checked the clock motor and it was good. Intermatic Pool Timer, tips & troubleshooting - YouTube Donna Simpson Eating Website But What Toilet? Ive reset the time 5 times and just realized that its going counter clockwise. by Intermatic Technical Support | Jul 25, 2022 Helpful? The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. When I put the new one on, the trippers do not work. I noticed that they had stopped. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. Pool timer malfunction - DoItYourself.com Community Forums Turn on / off manually work fine, but The clock gears still not moving. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. Thank you. we purchased the house 5 years ago so not sure how old the timer is? How to Install the Trippers on Intermatic Timers | eHow Why do we stock so many pool parts? Thanks in advanced. Voltage is 243, frequency is 60hz. If after verifying you have power to the timer, then check these things to further troubleshoot. The 10 Best Pool Timers - Pool Care Guy Thanks for your help! I made sure the trippers were fully inserted and tight. Hi Davy, Then remove the mechanism by pressing the clip at the top of the timer box. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. Many thanks! Confused. The same happens prior to the timer reaching the off tripper. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. Now, Im going to order some additional timer clips. Look to see if the clock is set to the correct time. Give it a little squirt of WD-40 or similar lubricant. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). Also be sure that the front dial is engaged with the gear located behind the dial. Hi Matthew T104 can only turn one pump on and off. I had a thunderstorm last night and my power went off for like 3 hours. It should loosen up after a few goes when the grease and gunt dissolve. I bought a new timer and replace the T104 timer clock. "
Grab it, pull it towards you, move it around then place it back down. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Put them back on and tighten them. "author": {
I looked to see if the gears on the timer are running. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. Flip it from where it is now, to the opposite side. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. Same way, WD-40 or any light lubricating oil. It worked for a day but the day after it didnt work. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. },
The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. I looked through the visual motor check and the gear still moving fine. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. I have a Model T104P and have a new green on tripper attached. What is the problem? I have the same issue currently, and it makes no sense to me so far. Pool Timer Not Turning ON or OFF!! Turn in either direction and align the exact time-of-day on . Intermatic timers are a great addition to your pool set up but they can go wrong. I noticed one thing that the power from the breaker is going into the control panel. Sound right? Death By Audio / Levitation Speed Tripper Feedback Phasing Delay Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. Is this a bad timer mechanism or loose wire? So what would be the problem? Other causes include rusted springs, insect infestation and loose timer dogs. How to Repair a Pool Timer | DoItYourself.com White is usually neutral (for 115V power), and black/red are usually hot, but sometimes people dont always use the correct wire color. Replace a new T104. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. March 16, 2022 by WildRiverCountry. TORK Repair Questions & Solutions, Tips & Guides Page 2 - Fixya how do I check the manual over ride switch to see if it is off? Tighten down all brass screws securely, to hold all wires firmly in place. 'Why not Toowoomba?': Tourism body says water park a missed opportunity Check that the breaker is firmly pushed onto the bar, and is not loose. If you dont have the voltage here you have an issue with either the wiring or the breaker. Thanks! You can replace the entire mechanism or the gears. I called Intermatic and there is nothing you can do except check it every time you have a power loss. "identifier": ""
do i need to do something different? Hello. Hello. It randomly loses the time that it is set to. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. Dead as a door nail. I am using the breaker to turn on and off the pool pump. Hey there! The problem lies where the power dies, youve probably heard that before. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. Why is my water heater timer not working? - Quick-Advices Theres power to the pump using the manual override. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Im ready to send my back for a replacement. Is it Necessary? The mechanism for the off tripper doesn't work at all when manually depressed. Any suggestions as to how to test clock feed? Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. "dateModified": "1/10/2020",
I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. As you release the dial, you will feel the gears engage. Some of the replacement motors make it past quality control with the incorrect gear setup. Any ideas? I can manually turn it on with the lever at the bottom. Second thing to check is the dial bent or warped, in that area where the on tripper is? Any advice? To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. Turn the power off at the breaker box and carefully remove the wires to the clock. If its not, it wont work properly. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). Turn the manual on/off switch. I have an intermatic timer thats 2 years young. Move the start and stop pins to appropriate times for swimming pool filter operation. Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. Line is incoming, Load goes to the pump. Gold OFF tripper works for all models. The timer quit after a nearby lightning strike. Faulty Pump or Wiring from the Timer to the Pump. It just stays at that time. It is a mechanical issue between the trippers and the switch lever. Pool Timer Parts - Pool and Spa PartsFinder | In The Swim It is an ON tripper right? Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Switch the breaker off at the power board. I have a PF1112T. Intermatic T100 Series Replacement Trippers for Timers 156T1978A - The Almost like it doesnt have the strength to click the timer on or off. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. i would like to use a timer but am now afraid to try another. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. The most common pool timer used for inground pool pumps is the Intermatic time clock. The pool was running on a timer. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am.